HoverMatt® Reusable Mattress

Reusable air-assisted mattress for patient transfers, boosting and positioning

Efficient patient handling
The HoverMatt air transfer system makes lateral patient transfers easier for caregivers and patients. When inflated, a cushion of air beneath the mattress reduces the pull force required to move the patient by 80 – 90%, enabling caregivers to transfer patients safely without lifting or straining. By virtually eliminating the injuries related to transfers and positioning, the HoverMatt significantly improves staff satisfaction and retention while reducing direct and indirect workers’ compensation costs.

Improves patient comfort & safety
An inflatable mattress cradles the patient while moving them in a stable position, eliminating skin shear and bruising and providing comfort for patients in pain. One device can be used for multiple patient-handling tasks across the facility, including radiology, diagnostic imaging, and ancillary departments.

Double-coated version
The double-coated models offer fluid and stain resistance, making them ideal for the OR and labour & delivery.

Features

HoverMatt® Reusable Mattress

Lower caregiver injuries

HoverMatt reduces the force required to move patients by 80-90%, preventing work-related injuries.
HoverMatt® Reusable Mattress

Improves caregiver productivity

As Hovermatt requires fewer caregivers, staff efficiency is improved.
HoverMatt® Reusable Mattress

Comfortable patient experience

The inflated mattress cradles the patient while moving them in a stable position. Skin shear and bruising will eliminates and provides the patient comfort in pain.
Eliminates bacteria pathways

Eliminates bacteria pathways

The HoverMatt has a heat-sealed construction that eliminates holes that are potential bacteria pathways.

Variants

Item number
Height (mm)
Length (mm)
Material
Maximum user weight (kg)
Pieces per pack
Width (mm)
HoverMatt Mattress 28" heat-sealed HM28HS 180 1980 Nylon (Latex free) 544 1 710
HoverMatt Mattress 34" heat-sealed HM34HS 180 1980 Nylon (Latex-free) 544 1 860
HoverMatt Mattress 39" heat-sealed HM39HS 180 1980 Nylon (Latex-free) 544 1 990
HoverMatt Mattress 50" heat-sealed HM50HS 180 1980 Nylon (Latex-free) 544 1 1270
HoverMatt Mattress 28" double-coated HM28DC 180 1980 Nylon with silica polyurethane coating. 544 1 710
HoverMatt Mattress 34" double-coated HM34DC 180 1980 Nylon with silica polyurethane coating 544 1 860
HoverMatt Mattress 39" double-coated HM39DC 180 1980 Nylon with silica polyurethane coating 544 1 990
HoverMatt Mattress 50" double-coated HM50DC 180 1980 Nylon with silica polyurethane coating 544 1 1270

In between patient uses, the HoverMatt should be wiped down with a cleaning solution used by your hospital for medical equipment disinfection. A 10:1 bleach solution (10 parts water: one part bleach) or disinfectant wipes can also be used. It is important to follow the cleaning solution manufacturer’s instructions for use, including dwell time and saturation. NOTE: Cleaning with a bleach solution may discolour fabric. If a reusable HoverMatt becomes badly soiled, it should be laundered in a washing machine with a 70° C maximum water temperature. A 10:1 bleach solution may be used (10 parts water: one part bleach) during the wash cycle. The HoverMatt should be air-dried if possible. Air drying can be expedited by using the air supply to circulate air through the inside of the HoverMatt. If using a dryer, the temperature setting should be set on the coolest setting. The drying temperature should never exceed 46° C). The backing of the nylon is polyurethane and will begin to deteriorate after repeated high-temperature drying. The Double-Coated HoverMatt should not be put in the dryer.